1、Program crash or crash


Problem phenomenon: the winding machine in the running process, the software suddenly stop responding, the interface is stuck, all operations can not be carried out.


Possible causes:


l The software itself has loopholes or defects, in the implementation of certain complex operations or failures after a long period of operation.


Insufficient computer system resources, such as high memory occupation, CPU overload, resulting in the software can not run normally.


l External interference, such as electromagnetic interference or unstable power supply, affects the normal operation of the software.


Solution:


l Restart the winding machine and software. If it is an occasional program crash, a simple restart may solve the problem.


l Check the computer system resources. Close other unnecessary programs to free up memory and CPU resources. Consider upgrading computer hardware, such as increasing memory, to meet the requirements of software operation.


l Update the software. Contact the device manufacturer for new versions of software patches or update programs to fix known software vulnerabilities.


l Check the power supply and electromagnetic environment. Use a voltage regulator to ensure a stable power supply, shield the equipment or keep it away from sources of interference to reduce electromagnetic interference.


 微信截图_20241203115119.png


2、Parameter settings can not be saved or error loading


Problem phenomenon: The winding parameters (such as the number of turns, wire diameter, speed, etc.) set up in the software cannot be loaded or saved correctly after the next boot or switching tasks.


Possible causes:


l The configuration file of the software is corrupted, which may be caused by the failure of the storage device, virus infection or abnormal shutdown.


l Insufficient software privileges to write or read the configuration file at the specified location.


l There is an error in the software's internal data storage logic.


Solution:


l Check the configuration file. If the configuration file is corrupted, try restoring it from a backup file (if one exists), or reset the parameters and save a new configuration file.


l Ensure that the software has sufficient permissions. Run the software as administrator, or check the permission settings of the software installation directory and configuration file storage directory to ensure that the software can read and write normally.


l Contact the software technical support, feedback data storage logic error, wait for the software developer to repair.


3, winding program running error


Problem phenomenon: The winding program does not meet the expected action in the running process, such as the flying fork action sequence is wrong, the winding speed changes abnormally, the number of turns counting is inaccurate.


Possible causes:


l Logic error in the program code, which may be a mistake in the software writing process or a new problem introduced in the updating process.


l Communication failure between the software and hardware, resulting in the instructions issued by the software not being correctly communicated to the hardware for execution.


l Hardware failure causes the software to receive incorrect feedback information, thus affecting the normal operation of the program.


Solution:


l Check the running log of the program. The software usually records key information during the running process. By checking the logs, you can find out where the program went wrong and the possible causes. According to the log information, contact the software developer for targeted repair.


l Check the communication connection between the software and hardware. Ensure that the communication line is normal, the interface is firmly connected, and the communication protocol is correct. You can use a professional communication test tool to detect whether the communication is normal.


l Check all the hardware. Exclude the impact of hardware failure on software operation, such as checking whether the sensor is working properly, whether the motor is running normally, etc.. If the hardware is faulty, repair the hardware problem first, and then observe the software operation.


4、Software interface display abnormality


Problem phenomenon: the software interface appears garbled, incomplete graphic display, button function failure and so on.


Possible causes:


l The software version is not compatible with the operating system, resulting in interface display problems.


l display driver problems, affecting the normal rendering of the software interface.


The interface resource file of the software itself is damaged.


Solution:


l Check the compatibility between the software and the operating system. Make sure that the software version used supports the current operating system, you can try to find the compatible software version on the official website of the device manufacturer and update it.


l Update the display driver. Find the display adapter through the device manager, right-click and select Update Driver, follow the prompts to complete the update operation to ensure that the software interface can be displayed normally.


l Repair or replace corrupted interface resource files. You can try to reinstall the software to restore the damaged resource files, or extract the corresponding resource files from the software installation package to replace them.



※ If you still can not solve the problem through the above ways and means, please contact the technical specialists of Xinhui Mechanical and Electrical Equipment Co.