What are the common electrical faults and their solutions for motor motor rotor automatic rewinders?

For the common electrical faults of motor motor rotor automatic rewinding machine and its solutions, the following are some key points:

1, the machine does not respond:

Possible causes: incorrect wiring or power is not turned on.

Solution: Check and correct the wiring and make sure the main power switch is closed.

微信截图_20241202135613.png

2、Electrodes do not move:

Possible causes: not connected to the air supply, air pressure problems, air leakage, solenoid valve wiring error or damage.

Solution: connect the air source, check the air pressure gauge, replace the air tube, reconnect or replace the solenoid valve.


3, current malfunction:

Possible causes: secondary short circuit, incorrect connection or component damage.

Solution: exclude the short circuit, and notify the manufacturer for further inspection and repair.


4、Net voltage is too high or too low:

Possible causes: power grid fluctuations.

Solution: Check the power grid and wait for the voltage to return to normal.


5、Output current is limited:

Possible causes: load or loop resistance is too large.

Solution: Check the output loop configuration and reduce the current setting if necessary.


6、Sensor failure:

Possible causes: The sensor may be damaged or poorly connected, resulting in inaccurate test data.

Solution: Calibrate the sensor regularly and replace it when abnormalities are found.


7、Controller failure:

Possible causes: the controller may be damaged, resulting in the machine can not run normally.

Solution: Check the controller circuit board to confirm whether there is component damage, and repair or replacement.


8, power supply problems:

Possible causes: poor power line contact or unstable voltage.

Solution: Check the power supply line to make sure it is firmly connected and use voltage stabilizing equipment to ensure stable voltage.


The above solutions provide for the motor motor rotor automatic rewinding machine failure of the basic processing methods, help to quickly diagnose and repair the problem, to ensure the normal operation of the machine. ※ If you still can't solve the problem by the above ways and means, please contact the technical specialists of Xinhui Electromechanical Equipment Co., Ltd. through the page chat tool to seek help.